Poland · SZZ

Szczecin (EPSC): SIDs, STARs and runways for flight sim

Solidarity Szczecin-Goleniów Airport (EPSC/SZZ) serves Szczecin, Poland, at 154 ft above sea level. SkyNexus draws 11 SIDs, 10 STARs and 5 approaches here for flight sim, by runway, so you can see which ones belong to the runway in use. It has a single paved runway, 13/31, 2,500 m (8,202 ft) long. Below are example A320 and 737-800 takeoffs from the longer runway ends.

Free account. Load your SimBrief flight plan and the procedures appear on the map.

ICAO / IATA
EPSC / SZZ
Elevation
154 ft
Runways
1
Position
53.585, 14.902

SIDs, STARs and approaches at EPSC

SIDs, STARs and approaches at EPSC by runway
RunwaySIDsSTARsApproaches
13APNEZ1D, APNEZ1E, BINKA1D, NEHIM1D, PESEL1D, UNVOX1DBODLA1A, ELTUB1A, FARCU1A, OBDEJ1A, ZAWIK1AAPP RWY 13, RNP RWY 13
31APNEZ1F, BINKA1F, NEHIM1F, PESEL1F, UNVOX1FBODLA1B, ELTUB1B, FARCU1B, OBDEJ1B, ZAWIK1BAPP RWY 31, ILS RWY 31, RNP RWY 31

From the official AIP (PANSA), AIRAC 2611.

SkyNexus draws 11 SIDs, 10 STARs and 5 approaches (1 ILS, 2 RNP and 2 VOR) at Szczecin, read from the official AIP (PANSA) and refreshed every AIRAC cycle. Load a SimBrief flight plan to or from EPSC and the ones you filed are drawn on the enroute map, with the altitude and speed limits at each fix. You can pick another SID, STAR or approach right on the map.

Zoom in on EPSC on the map for the ground diagram, with the stands at their stop positions, the holding positions and the taxiways, drawn from OpenStreetMap.

How the procedures look on the map · Airport diagrams · Coverage map

Runways at EPSC

Runway layout of EPSC13311,000 mN
RunwayLengthWidthHeading (true)SurfaceThreshold elev.
13/312,500 m8,202 ft60 m131° / 311°Asphalt, lit118 ft / 154 ft

Szczecin has one runway, so every departure and arrival uses 13/31, towards 131° or 311° true depending on the wind. With no second runway there is no crosswind alternative: on a day with strong wind across the field, the crosswind limit of your aircraft decides whether you can go.

Example takeoff performance

Flap setting, assumed temperature (FLEX) and V1/VR/V2 in knots for an A320ceo at 70 t and a 737-800 at 72 t, from the start of each runway of at least 1,800 m. Conditions are a standard day so runway length and airport elevation are what change: ISA temperature at the runway elevation, QNH 1013, calm wind, dry, no obstacles.

At these conditions the A320 takes off with CONF 3 and an assumed temperature of 55 °C from each runway end in the table, V2 142 kt.

At 154 ft above sea level the air is as dense as it gets, and the elevation costs nothing: the A320 example on 13 matches the same runway at sea level (CONF 3, 55 °C).

Near its maximum takeoff weight, at 77 t, the A320 example gets CONF 3 with an assumed temperature of 45 °C from each runway end. Runway length does not limit a full A320 here on a standard day; heat, a tailwind or a wet runway would change that.

RunwayOATA320ceo flap / FLEX, V1/VR/V2737-800 flap / assumed, V1/VR/V2
132,500 m14.8°C3 / 55°135/138/1425 / 67° max144/146/154
312,500 m14.7°C3 / 55°135/138/1425 / 67° max144/146/154

The A320 V2 values include improved climb: with a long runway and a high assumed temperature, V2 is raised above its minimum so the one-engine climb gradient still holds. That is why V2 runs higher on the longer runways.

The 737-800 assumed temperature is at its FCOM maximum (marked max) from each runway end in the table, so at 72 t the runway is not what limits it.

An illustration for flight simulation, not for real-world operations. Your own numbers depend on weight, weather, runway condition, intersection and obstacles; SkyNexus computes them from your SimBrief plan and the live METAR. See the A320 performance calculator and the 737-800 performance calculator for how it works.

Charts and VATSIM at EPSC

SkyNexus shows live VATSIM and IVAO ATC along your route.

EPSC questions

How long is the longest runway at EPSC?
Runway 13/31 at Szczecin is 2,500 m (8,202 ft) long and 60 m wide, surfaced in asphalt.
What is the elevation of Szczecin?
Solidarity Szczecin-Goleniów Airport sits at 154 ft above sea level. Elevation lowers air density, which raises true airspeed at a given V-speed and lengthens the takeoff run, so it matters for performance.
Which flap setting does an A320 use for takeoff at EPSC?
In our reference example (70 t, ISA, calm wind, dry runway, full length) the A320 uses CONF 3 here. On a real day the answer moves with weight, temperature, wind and the runway condition; SkyNexus works it out from your SimBrief flight plan and the live METAR.
Which runway at EPSC limits a heavy A320 takeoff?
Near its maximum takeoff weight, at 77 t, the A320 example gets CONF 3 with an assumed temperature of 45 °C from each runway end. Runway length does not limit a full A320 here on a standard day; heat, a tailwind or a wet runway would change that.
Which SIDs does EPSC have?
Szczecin has these SIDs, by runway. Runway 13: APNEZ1D, APNEZ1E, BINKA1D, NEHIM1D, PESEL1D, UNVOX1D. Runway 31: APNEZ1F, BINKA1F, NEHIM1F, PESEL1F, UNVOX1F. The STARs and approaches are on this page too.
Where can I find EPSC charts for flight sim?
ChartFox has the official charts for Szczecin. The SkyNexus map draws the SIDs, STARs and approaches this page lists (11 SIDs, 10 STARs and 5 approaches here), so you can follow your procedure on the map while you fly.
Does SkyNexus have SIDs and STARs for EPSC?
Yes. SkyNexus draws 11 SIDs, 10 STARs and 5 approaches (1 ILS, 2 RNP and 2 VOR) at Szczecin on the map, read from the official AIP (PANSA) and refreshed every AIRAC cycle. It is free with a SkyNexus account.

Get your own numbers for EPSC

Import your SimBrief flight plan and SkyNexus works out takeoff and landing performance for today's weather. Free, in the browser.

Open SkyNexus

Airport and runway data from OurAirports (public domain). Not for real-world navigation.